ACOUSTIC
MEASUREMENTS
YFU is
able to make several type of acoustical measurements with well developed instruments. As
known, because of the naturally complex characteristics of sound, acoustical measurements
are difficult and necessitate expensive instrumentation and a wide knowledge plus
experience. YFU has made the
necessary investment for such measurements for years ago, and developed experience and
knowledge over many years carrying out lots of acoustical measurements. Below, these
measurements, carried out according to international standards, are indicated shortly :
- Noise Level Measurements. Below
listed measurements can be done in wide band (16 - 20.000 Hz.) or in any frequency band
required. Frequency bands can be selected to be 1/1 octave or 1/3 octave..
- Instantaneous noise level (SPL)
- Average noise level in a certain period (Leq)
- Maximum noise level in a certain period (Lmax)
- Minimum noise level in a certain period (Lmin)
- Highest peak value in a certain period (Lpeak)
- Equivalent average noise level reduced to one second and having the same energy as a
time-limited noise (SEL)
- Statistical measurements giving intervals of noise levels with related percentage of
time
- Statistical measurements giving the parameters (L01, L10, L50,
L90, L99 or any set of five self determined L##)
- Production of pink noise and standard noises Spectrum I
and Spectrum II (used in noise transmission loss measurements)
up to a level of 118 dB for making measurements
- Frequency analysis
- Frequency analysis possibility in 1/1, 1/3, 1/12, and 1/24 octave bands
- Dual channel measurement possibility
- Intensity probe measurements
- Measurement of frequency response (and resonance frequencies) of a room
- If necessary and sufficient conditions are provided, measurement of noise transmission
loss between to rooms
- If necessary and sufficient conditions cannot be obtained, indirect measurement of noise
transmission loss between to rooms (using Spectrum I and Spectrum II standard noises)
- Reverberation time measurements
- Reverberation time measurements in frequency bands (1/1 or 1/3). Results are given as T60
using three different calculation methods (EDT, T20 and T30)
- Possibility to obtain a graphical output for the change of sound level during
reverberation time

For comments please send an e-mail to Osman